Description
Interface module for installation behind (rocker) switches or retractive switches. Suitable for controlling various X10 (actuators) through ON, OFF, DIM, BRIGHT, All Lights On, All Units Off or All Lights Off commands.
The IMX10 can also be used behind a (rocker) switch or retractive switch to start programming macros in, for example, a XanuraHome Control Box.
Inputs are only suitable for potential-free switches or contacts <+5 volts with respect to Neutral.
|
|
Features
- Can send ON, OFF, DIM, BRIGHT, All Lights On, All Units Off or All Lights Off commands (depending on the programming);
- Four inputs can be programmed independently in terms of address (A1 to P16) and function;
- Adjustable for fixed mode or toggle mode sending of ON/OFF commands;
- The dimmer interface is adjustable for use with retractive switches with one or two, normally open contacts (optionally with zero position, multi-switch);
- Can be used as mechanical ventilation interface in combination with a retractive switch with four normally open contacts with zero position (multi-switch);
- Adjustable for automatic request for status information (two way communication, status request);
- Adjustable for receipt of group commands for a status update in toggle mode;
|
|
Applications
Suitable for the connection of:
- Four 1-pole (rocker) switches;
- Four 1-pole, normally open contact, retractive switches;
- Two retractive switches with two normally open contacts (optionally with zero position, multi-switch) ;
- One retractive switch with four normally open contacts (optionally with zero position, multi-switch) ;
- Four random potential-free contacts with a common contact (P contact);
|
Technical information
- Rated voltage 230 Vac, 50 Hz;
- Current consumption < 30 mA capacitive;
- Signal transmission > 5 Vpp in 5 O at 120 kHz in accordance with EN 50065-1, EN 50065-2-1, EN 50065-4-1;
- Transmission synchronization 1 pulse burst at 0°/180°;
- Signal sensitivity 25 mVpp…6 Vpp at 120 kHz ± 4 kHz;
- Signal/noise ratio 1,35 : 1;
- Connection range Up to 2.5 mm2, tightening torque 0.5 Nm;
- Minimum ambient temperature 0 °C;
- Maximum ambient temperature 40 °C ;
- Atmospheric pressure 86 pkA - 106 pkA;
- Relative humidity (non condensing) 30 tot 90%;
- Standards NEN-EN-IEC 60669-2-1, NEN-EN-IEC 60669-2-2;
|