Description
The signal transmission of high frequency pulses via the mains network can be affected by active or passive interferences. When used correctly, the filter/phase coupler will extensively suppress these interferences.
The signal blocking filter is designed to be installed at the input of the consumer unit breaker panels or fuse boxes. This allows X-10 signals to pass between different wiring circuits, but prevents them from leaving the household and interfering with X-10 equipment in nearby homes.
|
|
Applications
Best for apartments and X10 systems installed in close range.
|
Technical information
Voltage: 230 V +10%/-15% 50Hz
Current: 200 A
Filter Frequency: 120 KHz
Filter Bandwidth: 5 KHz min. (3dB points)
EMC Emission: According to EN50081-1
EMC Immunity: According to EN50082-1
Electrical Safety: According to EN60950 and EN60065
Dimensions: 72 x 76 x 52 mm
|
|
Warning
For professional use! When installing consult an electrician.
|