Description
The GS-130 detects all mixtures of air and combustible gas (Natural Gas, Methane, Propane, Butane, Acetylene, GPL, Hydrogen, etc). The detector detects two levels of gas concentration - with corresponding output reactions.
The main GS-130 features are: high reliability and sensitivity, compact size, 230V (110V optional) power supply and long stability & lifetime.
|
Technical information
- Power supply: 230V/50Hz (optionally 110V/60Hz), 5W;
- Detection method: hot wire type;
- Sensitivity of 1st level: 10 % LEL;
- Sensitivity of 2nd level: 20% LEL;
- Buzzer sound level: 94dB/0.3m;
- Relay output: optional for 1st or 2nd level, max.230V/5A;
- Alarm memory: selectable;
- Response time: less then 5 s;
- External signaling AUX connector;
|