Description
The JA-60G detects all mixtures of air and combustible gas (Natural Gas, Methane, Propane, Butane, Acetylene, GPL, Hydrogen, etc).
|
|
Features
The detector detects two levels of gas concentration, responding with two different output reactions. The main detector features are: high reliability and sensitivity, compact size, 230V (110V optional) power supply and long stability & lifetime. It has a built-in transmitter to wirelessly send an alarm signal.
|
Technical information
- Power: 230V/50Hz (optional 110V/60Hz), 5W
- Detection Method: hot wire type
- 1st Level Sensitivity: 10 % calibrated for methane
- 2nd Level Sensitivity: 20% LEL calibrated for methane
- Buzzer: 94dB/0.3m
- Relay Output: optional for 1st or 2nd level, max.230V/5A
- Alarm Memory: selectable
- Response Time: 10 s
- Warm up Time: 30 s
- Range: max. 50m (open field)
- Temperature: -10°C to +40°C (operating)
- Norms: EN 60335-1
|