    Two load appliance in-wall module

    €28.90 excl tax
    The S2268HE module allow to control two individual loads, being small enough to fit behind a wall switch or junction box. It allows to control both internal relay either using any conventional electric switch (push buttons are not supported) or remotely, using any X-10 compatible controller.

    This module has a special feature which allows setting 16 distinct X-10 addresses to each internal relay. This is very useful to create macros.
    SKU: S2268HE

    Features:

    • Allows to control 2 individual loads either locally or remotely, using any compatible X-10 controller;
    • Potential free inputs, compatible with electric switches (push buttons are not supported);
    • Can be programmed to receive group commands (e.g. All Units Off);
    • Can  be programmed to accept until 16 X-10 address (per load);
    • Compatible with all X-10 devices;
    • Higher receiving sensitivity (25mVpp).



    TechInfo:

    • Supply voltage: 230V +/- 10% 50Hz;
    • Power consumption: <1 W;
    • Maximum load (by output):
      • Resistive loads: up to 8A;
      • Indutive loads: up to 1.5A;
      • Electric Transformer: up to 5A;
    • Ambient temperature: -10C to +50C;
    • Receiving signal sensitivity: 25mVpp;
    • Dimensions: 47mm x 51mm x 21mm;









    Write your own review
    • Only registered users can write reviews
    • Bad
    • Excellent

    Features:

    • Allows to control 2 individual loads either locally or remotely, using any compatible X-10 controller;
    • Potential free inputs, compatible with electric switches (push buttons are not supported);
    • Can be programmed to receive group commands (e.g. All Units Off);
    • Can  be programmed to accept until 16 X-10 address (per load);
    • Compatible with all X-10 devices;
    • Higher receiving sensitivity (25mVpp).



    TechInfo:

    • Supply voltage: 230V +/- 10% 50Hz;
    • Power consumption: <1 W;
    • Maximum load (by output):
      • Resistive loads: up to 8A;
      • Indutive loads: up to 1.5A;
      • Electric Transformer: up to 5A;
    • Ambient temperature: -10C to +50C;
    • Receiving signal sensitivity: 25mVpp;
    • Dimensions: 47mm x 51mm x 21mm;









    Customers who bought this item also bought

    Micromodule Open/Close (for shutters)

    €43.82 excl tax €59.99 excl tax
    This module was designed to control electric shutters or curtains.

    DIN rail On/Off

    €48.77 excl tax €69.99 excl tax
    This module has an On/Off output and is designed to be installed in DIN rails.

    This equipment is X10 compatible and is an alternative to the EOL AD10 and AD11

    Plug On/Off - Type F (Shucko)

    €36.58 excl tax €44.99 excl tax
    The plug-in On/Off module gives you elegant and stylish remote control of your lamps and appliances. Send commands to turn on/off the device using any Insteon or X10 module. Create scenes which include both your lamps and hardwired lights to create dramatic lighting scenes that really set the mood.
    This version is intended to be used with Shucko plugs (used in Portugal, Germany, Spain, etc.)

    Wireless Wall Switch (refurbished)

    €27.63 excl tax
    The slimline wireless wall switch (SS13E) lets you control three modules from any where in your home. The SS13E is normally used with the TM13E transceiver which passes through all codes from the wireless wall switch onto the powerline to control X10 modules. You can also use the wireless wall switch with any X10 security system instead of the TM13E.

    Universal Alarm Interface

    €36.58 excl tax
    Connects to an existing system and turns on lights when tripped. It has 3 modes of operation:
    In mode 1 the SM10 will turn On all Lamp Modules and Wall Switch Modules set to its House code, and will also turn On any other Modules set to its Unit code, a stereo connected to an Appliance Module, for example. All Lamp Modules and Wall Switch Module are left in the On state when the system is deactivated, but the Module set to the same Unit code as the SM10 will turn Off.
    In mode 2 the SM10 will FLASH all lights connected to Lamp Modules or Wall Switch Modules. All Lamp and Wall Switch Modules will be left in the On state when the system is de-activated but Appliance modules set to the same House code as the SM10 will turn Off.
    In mode 3 the SM10 will turn ON any Module set to the same House Code and Unit Code as the SM10 when the system is activated and turns it OFF when the input contact is opened.
    Set the input switch to A for triggering the interface by a low voltage input (6-8 V AC, DC or audio), to B for triggering the interface by a dry contact closure. Do not connect 220V to the input terminal!
    The SM10 has a test button which allows you to activate it whether or not it is connected to a system. The All light off button allows you to turn off anything which has been turned on by the interface.
    To install the SM10 (is expected to be installed inside the security controller panel) :
    • Connect the system output to the screw terminals.
    • Connect the flying lead to the 230V power supply, most likely at the 230V side of the transformer.