February 2009 |
|
|
|
|
|
|
Timed control (electrical heating) |
Installation: |
|
(very easy) |
|
MT10 + AM12G (up to 4): |
Task |
Timed control. For a 24-hour period, the time mini-programmer can connect up to 4 heaters during 4 different periods (one period per device). So, a solution with a MT10 and up to 4 AM12G connected to 4 electrical heaters can manage a different time profile for each heater. |
Description of the solution |
The MT10 connected to any 230V socket sends X10 ON/OFF commands to the AM12G receivers up to a maximum of 4. It also allows real time control of up to 8 X10 addresses.
Other X10 modules can be controlled through the MT10 |
|
Developments |
MT12 – The use of the MT12 instead of the MT10 allows for a maximum of 8 controlled Heaters, each with 4 different periods. CM15 – By replacing the MT10 with the CM15, PC module, we are able to control, by means of the ActiveHomePro software, 256 X10 addresses and formulate advanced macros. So, it allows us to control the required number of heaters up to a 256 limit, as well as to create different time profiles for workdays, weekends or holidays. |
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the heaters (by radio frequency)
|
Price table |
|
|
|
|
|
|
|
|
|
Timed control (central heating) |
Installation: |
|
(easy) |
|
MT12 + UM7206E |
Task |
Central heating timed control by means of the automation of the corresponding gas or diesel boiler. |
Description of the solution |
The MT12 is a mini timer that allows you to program the boiler for 4 time periods a day. It also allows real time control of the boiler by means of the adequate interfaces. The UM7206E is an X10 universal receiver that receives the X10 signals sent by the MT12 ordering the boiler to connect or disconnect the heating. Please note that the UM7206E interface does not interrupt the boiler's power supply, but since it is connected to the external thermostat inlet, it allows to activate or deactivate the heating. Check connection scheme. |
|
Developments |
CM15 – By replacing the MT12 with the CM15, PC module, it is possible to control, by means of the ActiveHomePro software, 256 X10 addresses and formulate advanced macros. So it allows us to create different time profiles for workdays, weekends or holidays. |
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the boiler (by radio frequency)
|
Price table |
|
|
|
|
|
|
|
|
|
Timed control (air conditioning, inside units) |
Installation: |
|
(easy) |
|
MT12+S3011(up to 4) |
Task |
Timed control. For a 24-hour period, the time mini-programmer can control up to 4 air conditioning inside units during 4 different periods (one period per device). |
Description of the solution |
The MT12 consists in a mini timer that allows to program AC inside units (up to 4) for 4 time periods a day. It also allows for real time control of the air conditioning inside units. The S30111 is an X10/IR (infrared) converter. This device receives the X10 signals sent by the MT12 and sends infrared signals accordingly. So, it is a solution for all air conditioning devices with an IR control.
|
|
Developments |
S3012 – Essentially, it is the same as the S3011; however, it is best suited for cases that allow “to conceal” the device inside a technical box, false ceiling, etc. By means of the infrared extension supplied, we are able to easily “camouflage” the system. CM15 – By replacing the MT12 with the CM15, PC module, it is possible to control, by means of the ActiveHomePro software, 256 X10 addresses and formulate advanced macros. So it allows us to create different time profiles for workdays, weekends or holidays. |
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the boiler (by radio frequency)
|
Price table |
|
|
|
|
|
|
|
|
|
Timed and cellular control (electrical heating) |
Installation: |
|
(very easy) |
|
SC28 + TS10 (up to 4) + AM12G (up to 4) |
Task |
Air conditioning by defining the comfort temperature at defined time intervals. |
Description of the solution |
The SC28 console receives temperature readings of up to 4 digital (TS-10) thermostats and sends X10 ON/OFF commands to 4 different (AM12G) actuators. The SC28 has several operation modes:
1. Normal mode, in which the comfort temperature is defined separately for each thermostat; 2. Comfort mode, in which the temperature is defined at the console and includes all thermostats; 3. Save mode, in which a lower temperature than the comfort mode is defined at the console and includes all thermostats; 4. Anti-freeze mode, in which an anti-freeze temperature is defined at the console and includes all thermostats.
Other X10 modules can be controlled through the SC28. The SC28 has an analogue phone communicator, so it allows remote control of the air conditioning. |
|
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the boiler (by radio frequency) |
Price table |
|
|
|
|
|
|
|
|
|
Timed and cellular control (electrical heating) |
Installation: |
|
(easy) |
|
MT12 + UM7206E + UC222 + TP-31 |
Task |
Central heating timed control by means of the automation of the corresponding gas or diesel boiler. Besides the time feature, the boiler responds according to the room temperature of the area you wish to condition. |
Description of the solution |
The MT12, connected to any 230V socket, sends X10 ON/OFF commands to the UM7206E universal module. The TP-31 wireless thermostat, fitted in the area you wish to condition, continuously reports the temperature to the UC-222 receiver which, in turn, switches its internal switch on or off. This way, within the time periods defined by the MT12, the boiler will activate the heating whenever the temperature drops below the comfort level. You can thus avoid the energy waste caused by the continuous use of the boiler within the defined periods. |
|
Developments |
CM15 – By replacing the MT12 with the CM15, PC module, it is possible to control, by means of the ActiveHomePro software, 256 X10 addresses and formulate advanced macros. So it allows us to create different time profiles for workdays, weekends or holidays. |
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the boiler (by radio frequency) |
Price table |
|
|
|
|
|
|
|
|
|
Timed and cellular control (air conditioning, inside units) |
Installation: |
|
(very easy) |
|
SC28 + TS10 (up to 4) + S3011 (up to 4) |
Task |
Air conditioning by defining the comfort temperature at defined time intervals. |
Description of the solution |
The SC28 console receives temperature readings of up to 4 digital (TS-10) thermostats and sends X10 ON/OFF commands to 4 different (S3011) converters. The SC28 has several operation modes:
1. Normal mode, in which the comfort temperature is defined separately for each thermostat; 2. Comfort mode, in which the temperature is defined at the console and includes all thermostats; 3. Save mode, in which a lower temperature than the comfort mode is defined at the console and includes all thermostats; 4. Anti-freeze mode, in which an anti-freeze temperature is defined at the console and includes all thermostats.
Other X10 modules can be controlled through the SC28. The SC28 has an analogue phone communicator, so it allows remote control of the air conditioning. |
|
Developments |
S3012 – Essentially, it is the same as the S3011; however, it is best suited for cases that allow “to conceal” the device inside a technical box, false ceiling, etc. By means of the infrared extension supplied, we are able to easily “camouflage” the system. |
Comfort increase |
With an UR81SLR or KR22 command and a TM13Greceiver, we are able to remotely control the heaters (by radio frequency) |
Price table |
|
|
|
|
|
|
|
|
|
Z-Wave timed and cellular control (radiators) |
Installation: |
|
(less easy) |
|
ZWIN03101 + ZWIN RA-PLUS-w |
Task |
Air conditioning by means of mechanical regulation of the central heating's radiators |
Description of the solution |
Each Z-Wave (ZWIN RA-PLUS-w) valve, has an embedded thermostat and transmits the information to the Innovus MyHome, Z-Wave (ZWIN03101) gateway, which manages the opening of the different valves according to the temperature and time of the day. Other Z-Wave modules can be controlled through the Innovus MyHome (ZWIN03101). The Innovus MyHome is an IP digital device, so it allows to remotely control the air conditioning, using the internet or a PDA. |
|
Developments |
Innovus SmoothRemote ZWIN04101 – Z-Wave comand that allows real time control of the radiators. |
Price table |
|
|
|
|
|
|
|
|
Cais do Lugan, n.º 224 2º dto. - 4400-492 Afurada - Vila Nova de Gaia - Portugal Tel: +351 223 744 938 - Fax: +351 223 745 167 - [email protected] - www.eurox10.com |
Please do not reply to this e-mail. To contact us use the e-mail: [email protected] |
|
|
|